Guangdong Pigeon Medical Apparatus Co.,Ltd
Guangdong Pigeon Medical Apparatus Co.,Ltd
Contact Us
PN3000-HFNC High Flow Nasal Cannula
PN3000-HFNC High Flow Nasal Cannula
PN3000-HFNC High Flow Nasal Cannula
PN3000-HFNC High Flow Nasal Cannula

PN3000-HFNC High Flow Nasal Cannula

Pigeon High Flow Nasal Cannula(HFNC) oxygen therapy is a form of non –invasive respiratory support,which comprises an air oxygen blender mixer, respiratory humidifier, a single heated circuit and a nasal cannula.It delivers adequately heated and humidified medical gas up to 60L/min,and is considered to have a number of physiological effects.


Working Principle of PN3000-HFNC High Flow Nasal Cannula


Pigeon adult HFNC adopts a soft, comfortable, lightweight breathing circuit and a unsealed high-flow nasal oxygen cannula to deliver a mixed high-flow gas to patient. Since the mask is not required, the patient can eat and talk without being affected while receiving treatment. After finishing machine connection, gas and oxygen come into blender and be adjusted to certain concentration,  inpired gas goes through humidifier and is heated to be with certain temperature and humidity, the machine has automatic temperature detection function, which makes patients' breath smoothly and comfortably.

Features of PN3000-HFNC High Flow Nasal Cannula


  • Automatical temperature detection

  • Stable performance

  • Mechanical type blender design.

  • Medical air compressor can be optional in the case of absence or failure of central air supply.


Specification of PN3000-HFNC High Flow Nasal Cannula


Adjustment of Oxygen ConcentrationMechanical
FiO221%-100%
Flow6-60LPM
Pressure of gas sourceAir/Oxygen@0.3-0.4 Mpa
Blender AlarmWhen gas supply pressure difference > 0.1 Mpa
Blender Alarm Noise>57 dB(A)
Accuracy of FiO20.03
Humidifier Supply Voltage/Frequency220V/ 110V   50/60Hz
Humidifier Temperature monitoring0-75℃
Humidifier Heater Plate Over-temperature Cut Off95±5℃
Heater Wire(Max.)22V-,2.73A, 60W, 50/60Hz
Humidifier Temperature control settingsHeated wire mode(mode indicator lighted)
Temperature grade(with indicator status)Continuous flow rangeDelivered patient temperature
P1 (●○○)5L/min-60L/min25-29℃
P2 (●●○)5L/min-60L/min29-35℃
P3 (●●●)5L/min-60L/min35-39℃
Non-heated wire mode(It is not recommended in adult HFNC. Operate manual of humidifier show details)